West Control Solutions 6600 1/16 DIN Temperature/Process Control with Heater Break Alarm

Not rated yet

West 1/16 DIN Temperature/Process Control, Universal Input, Self Tuning, Heater Break Alarm.

  • $574.00
Out of stock

ALL CONFIGURATIONS 1-3 WEEKS
The 6600 is an advanced PIDtemperature control that includes heater current monitoring & alarm.

6601 PID Control with heater break alarm
  • Heater Break Alarm
  • Auto or Manual Tuning
  • Heat/Cool Operation Option
  • Alarms Options
  • Amperage Display
  • ASCII or Modbus Comms Options
  • Configuration via PC Option
Features

Control Types - Full PID with Pre-tune, Self-tune, RaPID fuzzy logic, Manual Tuning, or On-Off control. Heat only or heat & cool.
Soft Start Allows the output to cycle during the process start-up phase.
Auto/Manual - Selectable from front panel with bumpless transfer.
Output Configuration - Up to 4 possible, for control (Heat & Cool), Alarms or (1) retransmit of Process Value or Setpoint.
Alarm Types - Heater Break, Process high, process low, SP deviation, band.
Heater Break Alarm Current Low or Current High (In absolute current of % of nominal current)
Human Interface - 4 button operation, dual 4 digit 10mm & 8mm high LED displays with Red Upper/Green Lower displays plus (3) Status LED's.
Manual or PC Configuration - Off-line configuration from serial port to dedicated config socket (comms option not required).

Input

Thermocouple - J, K, R, S, T, B, L & N Scalable within selected range.
RTD - 3 Wire PT100, 50ohm per lead maximum (balanced). Scalable within selected range.
Impedance - >10Mohm for Thermocouple and mV ranges
Accuracy - +/- 0.25% of input range +/- 1 LSD (T/C CJC better than 0.7C).
Sampling - 4 per second, 14 bit resolution approximately.
Sensor Break Detection - <2 secs (except zero based DC ranges), control O/P's turn off, high alarms activate for T/C low alarms activate for RTD
Heater Current 0-50mA secondary from external current transformer. Display can be scaled up to 100 amps. Current transformers available separately

Outputs & Options

Control & Alarm Relays - Contacts SPDT 2 Amp resistive at 240V AC, >500,000 operations.
Control SSR Outputs - Drive capability >10V DC in 500 ohm min
Solid State (Triac) Outputs - 0.01 to 1 Amp AC 20 to 280V, 47 to 63Hz.
Retransmit DC Outputs - 0-20/4-20mA into 500ohm max, 0-10/0-5V into 500ohm min. Accuracy typically +/- 0.25%.
Communications - 2 Wire RS485, 1200 to 9600 Baud, Modbus or West ASCII
Dual Setpoint Option using volt free or TTL input. Hold = -0.6 to 0.8V or contact open, Run = 2-24V or contact close.

Operating & Environmental

Temperature & RH - 0 to 55C (-20 to 80C storage), 20% to 95%RH non-condensing.
Power Supply - 90-264Vac 50/60Hz (standard); 4VA ; 20-55Vac 50/60Hz, 22 to 65VDC (option) & 22-65Vdc (option) 4W.
Front Panel Protection - IEC IP66 (Behind panel protection is IP20).
Standards - CE, UL & ULc. recognized.

Additional Information


Click to contact ISE with application assistance, product selection help or models not listed.   Additional models are available.

    • Weight
      3 lbs
    • SKU
      N6601
    • Mnf#/Vendor#
      N6601
  • Input
    0-800F J T/C, 0.0-800.0F J T/C, 0.0-450.0C J T/C, 0-1600F J T/C, 0-1000C J T/C, 0-2500F K T/C, 0-1373C K T/C, -199.9 - 999.9F K T/C, -128.8 - 537.7C K T/C, -199.9 - 752.0F T T/C, -128.8 - 400.0C TK T/C, 0-450C J T/C, -400 - 752F T T/C, -240 - 400C T T/C, 32 -3198F R T/C, 0 - 1759C R T/C, 32 -3204F S T/C, 0 - 1762C S T/C, 211 - 3315F B T/C, 100 - 1824C B T/C, 32 - 2551F N T/C, 0 - 1399C N T/C, -328 - 1401F PT100 RTD, -128.8 - 537.7C PT100 RTD
  • Output #1
    (1) Relay, (2) SSR Drive, (8) Triac
  • Output #2
    (0) None, (1) Heater Break Alarm Output, (1) Relay (High Alarm), (1) Relay (Low Process Alarm), (1) Relay (Cool), (2) SSR Drive (Cool), (8) Triac (Cool), (9) Dual Relay
  • Output #3
    (0) None, (1) Heater Break Alarm Output, (1) Relay (High Process Alarm), (1) Relay (Low Process Alarm), (7) Linear 4-20mADC Retransmit PV, (4) Linear 0-20mADC Retransmit PV, (5) Linear 0-5VDC Retransmit PV, (3) Linear 0-10VDC Retransmit PV, (7) Linear 4-20mADC Retransmit SP, (4) Linear 0-20mA Retransmit SP, (5) Linear 0-5VDC Retransmit SP, (3) Linear 0-10VDC Retransmit SP
  • Options
    (0) None, (1) RS485 Communications, (3) Dual Setpoint or Digital Input
  • Power Supply
    (0) 90-264 VAC Powered, Select
  • Display Color
    (2) Red Upper - Green Lower, Select
  • Manufacturer
    West
  • EC44-0
    • Power Supply
      Select
  • Agency Listing
    • UL
      Yes
    • cUL
      Yes
    • CE
      Yes
Customer reviews
Please sign in to add review
Please sign in to add review

Related products

Customers who viewed this product bought