Not rated yet
West Control Solutions 4700+ 1/4 DIN FM Approved High/Low Limit Control
SKU: 4700+
West 1/4 DIN High/Low Limit Control, Universal Input, Latching Output
Most Configurations Are In Stock For Same Day Shipment
We will advise immediately if your order will be delayed
The ISE/West 4700+provides a programmable safety cut out with optional outputs for annunciators and alarms. A latched relay cuts power to the process if it exceeds the safe value. The unit must be reset before the process can continue. Plug in direct replacement for the N4700 / N4701 series. We fully configure the control prior to shipment so that it is truly plug & play. Configurations can be easily modified if your requirements change. | |
| |
Features | |
Output Configuration - Up to 3 Total. 1 latching trip relay, max 2 alarms relays, max 2 DC linear retransmit (PV or limit value). Alarm 1 & 2 Types - Process high, process low, setpoint deviation, band, logical OR alarms or trip annunciator. Limit Action - Latching relay output when PV exceeds set value. Selectable for high or low trip activation. Output Reset Action - Limit output can be reset only when exceed condition is absent. Local or remote reset options. Annunciator Reset Action - Annunciator output can be reset at any time. Local or remote reset options. Human Interface - 4 button operation, dual 4 digit 13mm & 10mm high LED displays. Exceed, output & alarm indicators. Red Upper display / Green Lower Display Standard. Red Upper/Lower Optional. PC Configuration - Configuration via PC only. Dedicated config socket (comms option not required | |
Input | |
Thermocouple - J, K, R, S, T, B, L, C, Pt-Rh20% vs Pt-Rh40% & N. RTD - 3 Wire PT100, 50ohm per lead maximum (balanced). DC Linear - 0-20/4- 20mA, 0-50/10-50mV, 0-5/1-5/0-10/2-10V. Scaleable -1999 to 9999, decimal point selectable. Impedance - >10Mohm for Thermocouple and mV ranges, 47Kohm for V ranges and 5ohm for mA ranges. Accuracy - +/- 0.1% of input span +/- 1 LSD (T/C CJC better than 1C). Sampling - 4 per second, 14 bit resolution approximately. Sensor Break Detection - <2 secs (except zero based DC ranges), control O/P's turn off, high alarms activate for T/C and mV ranges, low alarms activate for RTD, mA or V ranges. | |
Outputs & Options | |
Limit Trip Relay - Contacts SPDT 5Amp resistive at 240V AC, >100,000 operations Alarm Relays - Contacts SPDT 2Amp resistive at 240V AC, >500,000 operations. SSR Drive - (Outputs 2 & 3 only) >10VDC into 500 ohm minimum. Triac - (Output 2 & 3 only) 0.01 to 1AAC, 20-280Vrms 47-63Hz Retransmit Outputs - 0-20/4-20mA into 500ohm max, 0-10/0-5V into 500ohm min. Accuracy typically +/- 0.25%. Communications - 2 Wire RS485, 1200 to 19200 Baud, West ASCII or Modbus selectable. Remote reset option - Allows remote latched relay and annunciator reset, using volt free or TTL input (Reset = -0.6 to 0.8V, or contact closure). | |
Operating & Environmental | |
Temperature & RH - 0 to 55C (-20 to 80C storage), 20% to 95%RH non-condensing. Power Supply - 100-240Vac 50/60Hz (standard) 7.5VA ; 20-50Vac 50/60Hz (option) 7.5VA & 22-65Vdc (option) 4W. Front Panel Protection - IEC IP66 (Behind panel protection is IP20). Approvals and Certification - CE, UR, cUR. & FM |
Additional Information
- Input0-800F J T/C, 0.0-800.0F J T/C, 0.0-450.0C J T/C, 0-1600F J T/C, 0-1000C J T/C, 0-2500F K T/C, 0-1373C K T/C, -199.9 - 999.9F K T/C, -128.8 - 537.7C K T/C, -199.9 - 752.0F T T/C, -128.8 - 400.0C TK T/C, 0-450C J T/C, -400 - 752F T T/C, -240 - 400C T T/C, 32 -3198F R T/C, 0 - 1759C R T/C, 32 -3204F S T/C, 0 - 1762C S T/C, 211 - 3315F B T/C, 100 - 1824C B T/C, 32 - 2551F N T/C, 0 - 1399C N T/C, -328 - 1401F PT100 RTD, -128.8 - 537.7C PT100 RTD, 0 - 20 mA Linear, 4 - 20 mA Linear, 0 - 50 mVDC Linear, 10 - 50 mVDC Linear, 0 - 5 VDC Linear, 1 - 5 VDC Linear, 0 - 10 VDC Linear, -199.9-999.9F PT100 RTD, -199 to 800C PT100 RTD, 2 - 10 VDC Linear
- Output #1(1) Relay (High Limit), (1) Relay (Low Limit)
- Output #2(0) None, (3) Linear 0-10VDC Retransmit, (5) Linear 0-5VDC Retransmit, (4) Linear 0-20mADC Retransmit, (7) Linear 4-20mA Retransmit, (6) Linear 2-10VDC Retransmit, (8) Triac (Low Process Alarm), (2) SSR Drive (Low Process Alarm), (1) Relay (Low Process Alarm), (8) Triac (High Process Alarm), (2) SSR Drive (High Process Alarm), (1) Relay (High Alarm), (1) Relay - Deviation Alarm, (1) Relay - Band Alarm
- Output #3(0) None, (1) Relay (Low Process Alarm), (1) Relay (High Process Alarm), (1) Relay - Deviation Alarm, (1) Relay - Band Alarm, (2) SSR Drive, (3) Linear 0-10VDC Retransmit SP, (5) Linear 0-5VDC Retransmit SP, (4) Linear 0-20mA Retransmit SP, (7) Linear 4-20mADC Retransmit SP, (3) Linear 0-10VDC Retransmit PV, (5) Linear 0-5VDC Retransmit PV, (4) Linear 0-20mADC Retransmit PV, (7) Linear 4-20mADC Retransmit PV, (8) Transmitter Power Supply
- Options(0) None, (1) RS485 Communications, (3) Digital Input (Remote Reset)
- Power Supply(0) 90-264 VAC Powered, Select
- Display Color(2) Red Upper - Green Lower, Select
- ManufacturerWest
- EC44-0
- Power SupplySelect
- Agency Listing
- ULYes
- cULYes
- FMYes
- CEYes