Specifications:
|
Operating Temp.: | 0 to 55C | Storage Temp.: | -20 to 80C | Humidity: | 20% to 95% non-condensing RH |
|
Supply Voltage: | 100 to 240V 50/60Hz; optional 20 to 48VAC / 22 to 65 VDC | Power Consumption: | 20VAmax |
|
T/Cs: | J, K, C, R, S, T, B, L, N, D, E and Pt 20% Rh vs. Pt 40% Rh | RTD: | 3-wire; PT100; NI120 50 per lead maximum (balanced) | DC Linear: (scalable 1999 to +9999) | Volts: 0-5V, 1-5, 0-10, or 2-10VDC DC milliamps: 0-20mA or 4-20mA DC millivolts: 0-50mV or 10-50mV |
|
All output types are user-selectable and customizable based on desired application; choose from the following output types: | Max. # of Outputs: | Nine for control, alarm, 24VDC transmitter power supply or retransmit of process value or setpoint (limitations apply, see full specification for available options) | Relay: | Optional SPDT; 240VAC 2.0A resistive. Lifetime: >500,000 operations at rated voltage/current. Reinforced safety isolation from other inputs and outputs. | Dual Relay | Optional SPST; 240VAC 2.0A resistive. Lifetime: >200,000 operations at rated voltage/current. Reinforced safety isolation from other inputs and outputs. |
|
| SSR Driver (single or dual): | Optional drive capability: >10VDC nominal into 500 minimum | DC Linear: | Optional 020mA , 420mA into 500 max.; 010V, 15V, 210V, 05V into 500 minimum; control outputs have 2% over/under drive applied; accuracy Â0.25% (mA into 250 load, V into 2k load); degrading linearly to 0.5% for increasing burden to specified limits | Triac: | Optional 0.01 to 1A AC, 20 to 280Vrms, 47-63Hz | Transmitter Power Supply: | Optional 24VDC (19 to 28VDC) into 910 ohm minimum (1 Max) |
|
All output functions are user-selectable and customisable based on the application: | Heat Power | reverse or direct | Cool Power | reverse or direct | Process Alarm: | reverse or direct | Alarms: | Up to 7 selectable as process high, process low, SP deviation, band, logical OR, logical AND alarm outputs, loop and rate of change. Alarms can be configured as latching | Loop Alarm: | reverse or direct | Retransmit: | setpoint or process value |
|
Accuracy: | 0.1% of input range 1 LSD (Thermocouple CJC) ; 0.25% of input range 1 LSD (Aux input) | Input Sample Rate: | Process input 10 per second, aux input 4 per second | Sensor Break Detection: | Detected within 2secs, control goes to user preset value |
|
Memory | 255 segments can be freely allocated in up to 64 programs. | Segment types | Ramp (rate or time), dwell (soak), hold, loop, join another profile, end or repeat sequence | Control | Run, hold, abort, profile select, jump to next segment, delayed profile start, real-time clock profile start |
|
Data record options | PV (process variable), max and min PV between samples, actual SP (setpoint), output power, alarm & event status, power on/off | Record modes | FIFO (circular buffer) or run-then-stop (fixed buffer) | Recording interval | 1, 2, 5, 10, 15, 30 sec or min | Control | Manual, serial comms, digital input, synchronised with profile, PV rate of change, log on alarm |
|
Options: | RS232 via RJ45 cable (configuration only), RS485 - Modbus RTU master or slave, Ethernet - Modbus TCP (10 base-T or 100 base-T), Ver 1.1/2.0 USB host for memory stick | PC Configuration: | Off-line configuration from serial port to dedicated configuration socket (comms option not required) |
|
Safety: | CE, UL, cUL | EMC: | Certified EN61326 | Other: | ISO 9002 registered |
|
- IEC IP66 (IP65 with USB fitted); NEMA 4X (front panel)
- IEC IP20 (behind the panel protection)
|
|
Panel Cutout: | 92mm x 92mm | Width: | 96mm | Depth: | 117mm | Height: | 96mm | Weight: | 0.65kg maximum | Mounting: | Plug-in with panel mounting fixing strap |
|