Ametek HDR PF1 350-500A SCR Power Controls

Model PF1 SCR Power Control (350-500A)

PF1, Single Phase, Phase Angle Control, 350-500A for Resistive, Transformer & Inductive Loads
Not rated yet
0
  • $3196.00
 

PF1 SCR Power Controls, Phase Angle (Single Phase, 350-500 Amps)

PF1 series SCR power controls are single phase, phase angle fired SCR power controls designed to deliver maximum power control with very high reliability. Phase angle fired units delay the turn on point in each half cycle of the sine waves for precise power control. This model can be used with resistive, inductive and transformer coupled loads. When the optional current limiting is utilized this model can be used with heaters that have a significant change in resistance during heat up. Other common applications for this model include IR heating and vibratory feeders.

General:

AC Voltage Input

AC Voltage Output

Recommended For RESISTIVE, INDUCTIVE & TRANSFORMER Loads

Phase Angle Fired

Can Be Used with Infra-Red Heaters and to control Vibratory Feeders

Delivery:

Shipment in 2 weeks (Expedited Delivery Possible).



Specifications:

Load Type:Resistive, Inductive and Transformer Loads
Control Method: Phase Angle Firing of back to back SCRs
Voltage Ratings:Models available for up to 600VAC
Current Ratings: 350-500 Amps
Command Signals:Most standard process signals are supported
Isolation:2500V RMS from power circuit to command signal and ground
Bias and Gain Adjustments: Multi-turn
Ambient Temperature Range:0-50 Degrees C Operating, 0-70 Degrees C Storage
Relative Humidity:0-95% Non-condensing
Agency Approvals:UL, cUL Listed, CE Compliant
Warranty:5 Years

Dimensions:

PF1 SCR Power Controil 350-500A Dimensions

Additional Information

Click Here to Download Product Manual

Click to contact ISE with application assistance, product selection help or models not listed.   Additional models are available.

    • SKU
      PF1 350-500A
    • Weight
      35 lbs
    • Manufacturer Part #
      PF1 350-500A
  • Voltage
    (120) 120 VAC, (240) 208 or 240 VAC, (400) 400 VAC, (480) 480 VAC, (575) 575 VAC
  • Current Rating
    (350) 350 Amps, 350-LG) 350 Amps with Line and Load Lugs, (500) 500 Amps, (500-LG) 500 Amps with Line and Load Lugs
  • Thermostat Option
    (NO) N.O. Thermostat, (NC) N.C. Thermostat
  • Options
    None, (CL) Current Limit and Over Current Trip, (OC) Over Current Trip, (CR) RMS Current Regulation, (PR) RMS Power Regulation
  • Command Signal Input
    (01) 4-20mA, (02) 0-10 VDC, (03) 0-5 VDC, (05) Manual Pot Input (Requires 5K Pot)
  • Manufacturer
    Ametek HDR
  • Made In USA
    No