Model PF1 SCR Power Control (800-1200A)

Not rated yet

PF1, Single Phase, Phase Angle Control, 800-1200A for Resistive, Transformer and Inductive Loads

  • $5255.00
Qty:  

PF1 SCR Power Controls, Phase Angle (Single Phase, 800-1200 Amps)

PF1 series SCR power controls are single phase, phase angle fired SCR power controls designed to deliver maximum power control with very high reliability. Phase angle fired units delay the turn on point in each half cycle of the sine waves for precise power control. This model can be used with resistive, inductive and transformer coupled loads. When the optional current limiting is utilized this model can be used with heaters that have a significant change in resistance during heat up. Other common applications for this model include IR heating and vibratory feeders.

General:

AC Voltage Input

AC Voltage Output

Recommended For RESISTIVE, INDUCTIVE & TRANSFORMER Loads

Phase Angle Fired

Can Be Used with Infra-Red Heaters and to control Vibratory Feeders



Delivery:

Shipment in 2 weeks (Expedited Delivery Possible).



Specifications:

Load Type:Resistive, Inductive and Transformer Loads
Control Method: Phase Angle Firing of back to back SCRs
Voltage Ratings:Models available for up to 600VAC
Current Ratings: 800-1200 Amps
Command Signals:Most standard process signals are supported
Isolation:2500V RMS from power circuit to command signal and ground
Bias and Gain Adjustments: Multi-turn


Ambient Temperature Range:0-50 Degrees C Operating, 0-70 Degrees C Storage
Relative Humidity:0-95% Non-condensing


Agency Approvals:UL, cUL Listed, CE Compliant
Warranty:5 Years





Dimensions:

PF1 SCR Power Control Dimensions





Additional Information

Click Here to Download Product Manual



Click to contact ISE with application assistance, product selection help or models not listed.   Additional models are available.

    • Weight
      85 lbs
    • SKU
      PF1 800-1200
    • Mnf#/Vendor#
      PF1 800-1200
  • Voltage
    (120) 120 VAC, (240) 208 or 240 VAC, (400) 400 VAC, (480) 480 VAC, (575) 575 VAC
  • Current Rating
    (800) 800 Amps, (800-LG 800 Amps with Line and Load Lugs, (1000) 1000 Amps, (1000-LG) 1000 Amps with Line and Load Lugs, (1200) 1200 Amps, (1200-LG1200 Amps with Line and Load Lugs
  • Thermostat Option
    (NO) N.O. Thermostat, (NC) N.C. Thermostat
  • Options
    None, (CL) Current Limit and Over Current Trip, (OC) Over Current Trip, (CR) RMS Current Regulation, (PR) RMS Power Regulation
  • Command Signal Input
    (01) 4-20mA, (02) 0-10 VDC, (03) 0-5 VDC, (05) Manual Pot Input (Requires 5K Pot)
  • Manufacturer
    Ametek HDR
  • Made In USA
    No