Rustrak Model 288

 
Rustrak 288 Recorder

Rustrak 288 Single Channel DC Input Recorders

  • DC Volts, Amps, mA, uA, mV Input Ranges are Available.
  • Custom scales are available to match any measured parameter.
  • Rustrak 288 Recorder Accuracy +/- 2 % of span.
  • Recorder Response time 1 second maximum.
  • Maximum Overload 200%, short term; 150% continuous.
  • Environment: Indoor/outdoor with suitable enclosure.
  • Recorder Operating temperature 0-60C (32-140F).
  • The Rustrak Recorder Utilizes pressure sensitive paper for recording.
  • Recording width 2-5/16" nominal.
  • Recorder Chart Speeds from 1/48"/Hour to 240"/Hour via motor & gear train.
  • Numerous Rustrak recorder options & accessories are available.

 

Available Input Ranges Rustrak 288 Recorder

DC Microamps DC Milliamps DC Amps DC Millivolts DC Volts
0-10 0-1 0-1 0-10 0-1
0-50 0-1.5 0-3 0-25 0-3
0-100 0-3 0-5 0-50 0-5
0-200 0-5   0-100 0-10
0-500 1-5     0-15
  0-10     0-30
  0-15     0-50
  4-20     0-75
  0-30     0-100
  10-50     0-150
  0-50     0-300
  0-75     0-500
  0-100      
  0-150      
  0-300      
  0-500      
  0-750      
DC uA DC mA DC A DC mV DC V

Rustrak Recorder Index Page

 
 

Information Request Form

Select the items that apply, and then let us know how to contact you.

Send product literature
Send company literature
Have a salesperson contact me

 Name: 
     Title: 
   Company: 
Address: 
	 
	 
City:   State:
Zip/Postal:   Country: 
    E-mail: 
     Phone: 
       Fax: 
 Send Quote
Input Signal: 
Scale:        
Power Source: 
Chart Speed:  
 
Additional Comments or Application Description

 

If the feedback form is not visible you need to download the flash player.  Refresh the page after installing the player.



[HRule Image]

Below are some links to our most popular web pages (click on the graphic to follow the link). For a complete listing click Products.

 

HOME

PRODUCTS

 

SEARCH

FEEDBACK

Track a shipment from ISE     Transit times for UPS Ground from ISE 

[HRule Image]

 

   

Headquarters
10100 Royalton Rd.,  Cleveland, OH  44133  USA
Phone: (440) 237-3200  Fax: (440) 237-1744
Email ISE Cleveland
 
Toledo Area Office
417 Tomahawk Drive,  Maumee, Oh 43537
Phone: 419-893-3330 - FAX: 419-893-2151
Email ISE Toledo  
 

ISE, Inc. Privacy Policy

Click for Cleveland, Ohio Forecast Copyright © 2008 ISE, Inc.  All rights reserved.