Laurel Electronics, Laurate DIN rail Signal Conditioner / Transmitter
Laurel Universal Transmitter / Signal Conditioner. Analog Input Options / Analog Output Options.
Stock to 1 Week Shipment Typical
We will advise immediately if your order will be delayed
Laurel Laureate Transmitters are a cost-effective solution to a wide range of monitoring and control applications, offering performance and programmable features not found in other transmitters.Exceptional flexibility is provided by software and hardware options for control, analog output, and serial communications.
The meters are economical and DIN rail mount.
Standard Features
Choice of 5 signal conditioners- DC volts, amps, process, strain
- Load cell, 6-wire, to 20mV FS
- True RMS volts & amps
- Thermocouple
- RTD & Ohms
Note: Extended DPM option adds rate of
change & linearization of nonlinear
inputs. Not applicable to
thermocouple or RTD inputs.
Analog Output (standard) Output Levels (Selectable)
- 4-20 mA, 0-20 mA, 0-10V, -10V to +10V
Exceptional accuracy
- 0.01% of FS for DC, load, process
- 0.1% of FS for AC RMS
- 0.3C for thermocouples
- 0.1C for RTDs
High-speed data collection
- 50 or 60 conversions/sec
- Adaptive digital noise filter
- 16 Bit(65,536 Steps) Input Resolution
Universal power
- 85-264VAC / 90-300VDC or 12-34VAC / 10-48VDC
Isolated 5, 10 & 24 VDC output
- Powers 4 load cells in parallel
Click to download literature
Click for Manual
Software Download
- ManufacturerLaurel
- Made In USAYes
- DPM
- Power Supply Options(0) 85-264VAC or 95-300VDC, (1) 12-34VAC or 10-48VDC
- Input(RMV1) RMS Volts: 200.00mV, (RMV2) RMS Volts: 2.0000V, (RMV3) RMS Volts: 20.000V, (RMV4) RMS Volts: 200.00V, (RMV5) RMS Volts: 600.0V, (RMV6) RMS Volts: 300.00V, (RMA1) RMS Amps: 2.0000mA, (RMA2) RMS Amps: 20.000mA, (RMA3) RMS Amps: 200.00mA, (RMA4) RMS Amps: 5.000A, (P1) Process Signal: Custom Scaling*, (SG1) Strain Gauge: Custom Scaling*, (WM1) Load Cells: -99,999 to +99,999*, (R0) Ohms: 0-2.0000 Ohm (Special Fixed Range), (R1) Ohms: 0-20.000 Ohm, (R2) Ohms: 0-200.00 Ohm, (R3) Ohms: 0-2.0000 kOhm, (R4) Ohms: 0-20.000 kOhm, (R5) Ohms: 0-200.00 kOhm, (R6) Ohms: 0-2.0000 MOhm (Special Fixed Range), (DCV1) DC Volts: +/-200.00mV, (DCV2) DC Volts: +/-2.0000V, (DCV3) DC Volts: +/-20.000V, (DCV4) DC Volts: +/-200.00V, (DCV5) DC Volts: +/-600.0V, (DCA1) DC Amps: +/-2.0000mA, (DCA2) DC Amps: +/-20.000mA, (DCA3) DC Amps: +/-200.00mA, (DCA4) DC Amps: +/-5.000A, (JC) Thermocouple: JC -210 to 760C, (JF) Thermocouple: JF -347 to 1400F, (KC) Thermocouple: KC -244 to 1372C, (KF) Thermocouple: KF -408 to 2501F, (TC) Thermocouple: TC -257 to 400C, (TF) Thermocouple: TF -430 to 752F, (EC) Thermocouple: EC -270 to 1000C, (EF) Thermocouple: EF -450 to 1830F, (NC) Thermocouple: NC -245 to 1300C, (NF) Thermocouple: NF -410 to 2370F, (RC) Thermocouple: RC -45 to 1768C, (RF) Thermocouple: RF -49 to 3213F, (SC) Thermocouple: SC -46 to 1768C, (SF) Thermocouple: SF -51 to 3214F, (P385C) RTD: Pt 100 Ohm Platinum -202 to 850C, (P385F) RTD: Pt 100 Ohm Platinum -331 to 1562F, (P392C) RTD: Pt 100 Ohm Platinum -202 to 631C, (P392F) RTD: Pt 100 Ohm Platinum -331 to 1168F, (N672C) RTD: Ni 120 Ohm Nickel -100 to 260C, (N672F) RTD: Ni 120 Ohm Nickel -148 to 500F, (C427C) RTD: Cu 10 Ohm Copper -100 to 260C, (C427F) RTD: Cu 10 Ohm Copper -148 to 500F, (SG) Strain Gauge: 0 to 200mV, (P) Process Signals: 4-20mA
- Main Board (LT)(2) Standard Analog Input, (4) Extended Analog (Includes custom linearization and rate from successive readings
- Alarm Outputs (LT)Dual SSR 120mA , 140VAC, 180VDC Max
- Communications (LT)RS232/RS485 (LT), Ethernet (LTE)
- (LT/LTE) Analog OutputSingle Analog: 4-20 mA, 0-20 mA, 0-10V, -10V to +10V Selectable