MLC-9000+ Control System (Replaces MLC-9000)
General
Literature
MLC 9000+ Installation &
Operation Manual
MLC9000+ BUS CONTROL MODULES
|
BASIC
Type:
Bus Control Module (BCM)
Protocol:
None
Ports:
Equipped with Partlow configuration port only
PC Configurable:
Yes
Construction:
BTP, DIN Rail Mount, black ABS plastic
|

 |
Provides:
Exceptional multi-zone temperature control
Literature |
|
 
Type:
Bus Control Module (BCM)
Protocol:
CANopen
Ports:
Equipped with Partlow configuration and CANopen ports
PC Configurable:
Yes
Construction:
BTP, DIN Rail Mount, black ABS plastic |

 |
Provides:
Exceptional multi-zone
temperature control within CANopen network
Literature |
|

Type:
Bus Control Module (BCM)
Protocol:
DeviceNet
Ports:
Equipped with Partlow configuration and DeviceNet ports
PC Configurable:
Yes
Construction:
BTP, DIN Rail Mount, black ABS plastic |

|
Provides:
Exceptional multi-zone
temperature control within DeviceNet network
Literature |
|
 
Type:
Bus Control Module (BCM)
Protocol:
Ethernet/IP
Ports:
Equipped with Partlow configuration and Ethernet/IP ports
PC Configurable:
Yes
Construction:
BTP, DIN Rail Mount, black ABS plastic |

 |
Provides:
Exceptional multi-zone
temperature control within Ethernet/IP network
Literature |
|
Type:
Bus Control Module (BCM)
Protocol:
MODBUS/TCP
Ports:
Equipped with Partlow configuration and MODBUS/TCP ports
PC Configurable:
Yes
Construction:
BTP, DIN Rail Mount, black ABS plastic |

 |
Provides:
Exceptional multi-zone
temperature control within MODBUS/TCP network
Literature |
|

Type:
Bus Control Module (BCM)
Protocol:
MODBUS/RTU
Ports:
Equipped with Partlow configuration and MODBUS/RTU ports
PC Configurable:
Yes
Construction:
BTP, DIN Rail Mount, black ABS plastic |

 |
Provides:
Exceptional multi-zone
temperature control within MODBUS/RTU network
Literature |
|

Type:
Bus Control Module (BCM)
Protocol:
PROFIBUS
Ports:
Equipped with Partlow configuration and PROFIBUS ports
PC Configurable:
Yes
Construction:
BTP, DIN Rail Mount, black ABS plastic |

 |
Provides:
Exceptional multi-zone
temperature control within PROFIBUS network
Literature |
|
|
MLC9000+ LOOP CONTROL MODULES
|
Single
Loop
Type:
Loop Control Module (LCM)
Input Type:
Universal
Input sample
rate:
10Hz (100msec)
Heater Break Alarm:
Optional
Outputs:
Two SSR/Relay, Linear
PC Configurable:
Yes
Construction:
BTP, DIN Rail Mount, black ABS plastic
|

|
Supports:
Up to 8 loops
in one rack |
Literature |
Three
Loop
Type:
Loop Control Module (LCM)
Input Type:
Universal
Input sample
rate:
10Hz (100msec)
Heater Break Alarm:
Standard
Outputs:
Six SSR or Six Relay
PC Configurable:
Yes
Construction:
BTP, DIN Rail Mount, black ABS plastic |

|
Supports:
Up to 24
loops in one rack |
Literature |
Four
Loop
Type:
Loop Control Module (LCM)
Input Type:
NEW Universal
Input sample
rate:
10Hz (100msec)
Heater Break Alarm:
None
PC Configurable:
Yes
Outputs:
Six SSR or Six Relay
Construction:
BTP, DIN Rail Mount, black ABS plastic |

|
Supports:
Up to 32
loops in one rack |
Literature |
|